Barkley Emergency Gate Machinery Inspection


Subject: Barkley Emergency Gate Machinery Inspection
Solicitation Number: W912P526QA023
Notice Type: SOLICIT
NAICS: 811310
Notice Published: 06-10-26
Response Due: 07-10-26

Agency: Department of the Army
Office: W072 ENDIST NASHVILLE
Contact: ROBERT ELLIS This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (615) 736-5632
Office Address: NASHVILLE, TN 37203-1070
Place of Performance: Barkley Lock, 758 Barkley Dam Road, Grand Rivers, KY, 42045 42045

Related Notices:
        07-13-26 SOLICIT


Click for official SAM (FBO) notice, additional information, and accompanying attachments

Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.