Sawyer Creek Culvert
Subject: Sawyer Creek CulvertSolicitation Number: W911S226U3442Notice Type: SOLICITNAICS: 331210Set-Aside: Total Small BusinessNotice Published: 06-16-26Response Due: 06-22-26Agency: Department of the ArmyOffice: W6QM MICC-FT DRUMContact: Carrie Lawton This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (772) 106-5Office Address: FORT DRUM, NY 13602-5220Place of Performance: T-84 1st St West Fort Drum, NY 13602 13602
Click for official SAM (FBO) notice, additional information, and accompanying attachments
5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections). Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering.