Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System


Subject: Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System
Solicitation Number: 75N98026Q00714
Notice Type: SOLICIT
NAICS: 334516
Set-Aside: No Set aside used
Notice Published: 07-09-26
Response Due: 07-20-26

Agency: Department of Health and Human Services
Office: NATIONAL INSTITUTES OF HEALTH
Contact: John Burton This email address is being protected from spambots. You need JavaScript enabled to view it.
Office Address: BETHESDA, MD 20892
Place of Performance: Bethesda, MD 20892


Click for official SAM (FBO) notice, additional information, and accompanying attachments

Requirements: To ensure continuity of research, NIAMS proposes the acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System. qPCR is a core technology used for nucleic acid amplification, quantification, and analysis and supports a wide range of research applications, including gene expression studies, pathogen detection, transcript quantification, and validation of experimental results. The QuantStudio 3 is the closest replacement to the current StepOnePlus systems, allowing researchers to maintain established workflows and consistency in experimental design and data interpretation. The QuantStudio 3 offers several operational advantages, including user-friendly software, compatibility with both Mac and PC platforms, touchscreen operation, and the ability to function as a standalone instrument or in conjunction with a computer. Its thermal block design is similar to the existing systems, minimizing the learning curve for users and supporting a broad range of genomic applications. In addition, the manufacturer offers trade-in credit for the current instruments, reducing the overall acquisition cost while providing access to a fully supported platform with available parts and technical support. Acquiring the QuantStudio 3 at this time will help prevent interruptions to research activities, maintain reliable and consistent data generation, and ensure that NIAMS laboratories have access to a supported and dependable qPCR platform. 4.1 PRODUCT FEATURES/SALIENT CHARACTERISTICS The contractor shall provide one Applied Biosystems QuantStudio 3 Real-Time PCR System or an equal system that meets all the following minimum requirements. 4.1.1. System Features/Benefits The system shall: ? Utilize a platform providing 1 TB or storage space for data sharing at user discretion ? be used with online scientific apps ? come with desktop-based software, allowing single-plate run setup and analysis. 4.1.2. Technical specifications ? Instrument The instrument shall: ? have a 96 well 0.1 ml plate block format and the option to run fast protocols <30 minutes ? not require a field service engineer for set up by end user. Set up should be easy for end user ? directly out of the box. ? not require a computer for installation ? use an RNase P verification plate to verify performance ? not require dye calibration upon installation ? have dimensions fo 27 x 50 x 40 cm and be designed to maximize horizonal and vertical bench space ? be capable of analyzing 96 samples simultaneously in various formats incluing both 96-well plates, 8-tube strips and individual tubes ? the 96-well block should be made of at least 3 separated Peltier elements ? VeriFlex Blocks. The maximum temperature difference programmable across the block should be 10 degrees C. 5 degrees C should be the maximum difference in temperature allowed between adjacent blocks. ? Support reaction volumes of 10-30 uL on 0.1mL the 96-well block ? Be factory calibrated with FAM, SYBR Green 1, VIC, NED, ABY, JUN, TAMRA, and ROX dyes ? Have melt or dissociation curves that take place in steps with deltaT varying between 0.015 degrees C and 3.66 degrees C ? Have a maximum block ramp rate of 9.0 degrees C/sec for the 0.1 mL block ? Have a block with a temperature range of 4-99.9 degrees celcius ? Have a heated cover with temperature range of 50-110 degreesC 2 ? Have a long-lasting bright white LED source with median lifetime of at least 60,000 hours ? Have a CMOS imager for data acquisition and collects data for each filter combination in less than 2 seconds ? be used with 120-240 V outlets without modification or special plug requirements ? Include a heated lid assembly to heat tops of sample plates and minimize reaction evaporation. 4.1.3 Technical specifications ? Instrument onboard computer The system shall: ? Possess the capability to run in stand-alone mode, without an attached computer ? Include a touchscreen interface and store protocols for quick starts with no computer needed ? Have a touchscreen interface that enables viewing amplification plots and filtering them by sample, target and task ? Have a touchscreen interface that facilitates uploading of protocols or downloading of run files via a USB, local network and the Connect platform ? Have a touchscreen interface that allows uploading of protocols and run files directly to the Connect platform ? Contain onboard storage with memory capacity of 10 GB for storing 1,000-5,000 standard absolute quantification run files, and be designed for run protection in case of power outages ? Be able to be customized through the touchscreen for time zones and service/calibration notification settings ? Have a touchscreen interface that supports the creation of local user accounts with PIN-protected access that can be linked to the Connect platform to online accounts on thermofisher.com ? Have a touchscreen interface that allows creation and running of protocols as guests ? Have a touchscreen interface that allows for editing of protocols at all stages of the reaction cycle as well as block settings, temperature settings duration, ramp rate, etc. ? Have a touchscreen interface that allows a template to be loaded from a USB, local network or the Connect platform ? Have a touchscreen interface that allows user to enter reagent information ? Have a touchscreen interface that allows a run to be paused and during that pause for the block temperature to be set as well as for the drawer to be opened and closed ? Have a touchscreen interface that allows editing of sample and target assignments ? Have a touchscreen interface that allows the repeat of a previous run 3 ? Have a touchscreen interface that allows users to perform dye calibrations and view results on the touchscreen ? Have a touchscreen interface that allows RNase P verification runs and automatically provides pass/fail results ? Have a touchscreen interface that allows a user to run a self-verification test ? Have a touchscreen interface that allows the user to view the cure QC assessment after calibration and RNase P plate runs are finished ? Have a touchscreen interface that allows progress monitoring. 4.1.4 Performance Requirements The instrument shall: ? Complete 40-cycle real-time PCR runs using fluorogenic 5? nuclease assay and Fast chemistry in a standard 96-well plate in less than 30 minutes as well as being able to run in standard ramping mode with standard chemistry ? Include an OptiFlex system that combines four coupled excitation, and emission filter sets to allow multiplexing up to four unique wavelengths ? Support at least two reaction chemistries-TaqMan? Probes and SYBR Green dye ? Have real-time quantitative PCR installation specifications to be able to distinguish between 5,000 and 10,000 template copies at a 99.7% confidence level. 4.1.5 Software Requirements The software shall: ? Allow flexible customization of run protocols ? Allow the creation of secure templates that are locked with a password to limit modification of run setup ? Provide run monitoring of connected instruments ? Include preoptimized run protocols for applications like standard curve, relative standard curve, relative quantification of gene expression, and SNP genotyping with TaqMan? or SYBR Green chemistries ? Include a copy of free software to analyze data for absolute and relative quantification, SNP detection and other assays. ? Collect information on both TaqMan and SYBR assays in the same run ? Have a genotyping optimization tool that uses real-time data ? Provide raw fluorescence data and multicomponent data for troubleshooting ? Allow conversion of protocols for the Applied Biosystems StepOnePlus and 7500 to the QuantStudio 3 system protocols ? Allow batch analysis of up to 500 experiments simultaneously ? Can control the instrument and analyze data from a remote computer on the same network 4 ? Provide status monitoring of connected instruments and real-time plots STATEMENT OF NEED (SON) ? Have the ability to send user notifications when a run is started, stopped or has an error ? Allow registered users of the Connect platform to monitor any connected instrument ? Allow users to run an assay plate without performing plate setup prior to beginning of run and to correct plate set up after the run ? Allow export of all run results to excel and save graphs as .jpg files ? Provide the ability to import a standard curve from one plate for analysis of another plate of the same instrument type ? Allow for the selection of endogenous controls for gene expression experiments ? Include statistical analysis tools including box-whisker plots, scatter plots and heat maps ? Allow preselection of data to export and the location of the exported file ? Allow for command-line functions for batch exporting of analyzed run files ? Allow users to save predefined analysis settings for auto-exporting run data into format of choice ? Contain online high-resolution melt application so user can specify number of clusters/variants and save defined controls and analysis setting. 4.1.6 Instrument Ecosystem The instrument ecosystem shall: ? Be part of a desktop ecosystem that consists of a suite of qPCR applications. Instrument data can be grouped (multi-plate) for relative quantitation, SNP genotyping, standard curve, HRM analysis, and presence/absence analysis. ? Be part of the Connect platform ? Be able to connect to the Connect platform for run setup download and data uploads ? Allow a run to be monitored by a web browser or mobile device ? Allow batch-analysis of up to 500 experiments simultaneously through an online relative quantitation module ? Provide an endogenous control selection tool for gene expression experiments in both the desktop and online quantitation software ? Contain statistical anaylsis tools with both the desktop and online quantitation software ? Contain a genotyping optimization tool that uses real-time data to pick the best cycle number for calling genotype in both the desktop and online genotyping software ? Allow the user to specify number of clusters/variants and save defined controls and analysis settings with both desktop and online software. 4.1.7. Design 5 The system shall: ? Have an application programming interface (API) included that allows programming routines to be developed for controlling the instrument ? Be cUL, UL, CE, C-TICK, and WEEE compliant ? Be developed and manufactured in a facility with quality system requirements that comply with ISO 13485 standards and ISO 9001 standards 4.1.8 Gene expression profiling ? Users shall be able to select from more than 61,000 predesigned human, mouse and rat Applied BiosystemsTMTaqMan? Assays. 4.1.9 Able to accept the trade-in of Model STEPONEPLUS. Serial number 272008444 4.1.10 Must be compatible with protocols from Applied Biosystems StepOnePlus Real Time PCR (qPCR) allowing for consistency in experimental set-up 4.2 DELIVERY / INSTALLATION The contractor shall deliver and install the equipment within thirty (30) calendar days after receipt of award.