Renovate Secure Facility B1049


Subject: Renovate Secure Facility B1049
Solicitation Number: FA9401-26-R-0024
Notice Type: SOLICIT
NAICS: 236220
Set-Aside: Total Small Business
Notice Published: 08-11-26
Response Due: 09-16-26

Agency: Department of the Air Force
Office: FA9401 377 MSG PK
Contact: A1C Tyler S. Hatfield, USAF This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (505) 853-8005
Office Address: KIRTLAND AFB, NM 87117-0001
Place of Performance: Kirtland AFB, NM 87117

Related Notices:
        09-16-26 SOLICIT

        08-14-26 SOLICIT

        08-31-26 SOLICIT

        09-09-26 SOLICIT

        09-09-26 SOLICIT

        08-11-26 SOLICIT


Click for official SAM (FBO) notice, additional information, and accompanying attachments

SITE VISIT: A site visit for interested contractors is scheduled for Friday, 28 August 2026 at 0930 MST. All parties will meet at Truman Gate Visitor Center to be sponsored onto base no later than 9:00 AM (MST). Attendance at the site visit will be limited to no more than two (2) representatives per company. Please allow extra time to obtain your pass. Attending the site visit is not required in order to be considered for award, but is highly encouraged so as to understand the site layout well. QUESTIONS: Please submit any questions regarding this opportunity at any time before 02 September 2026 at 4:00 MST. Questions may be answered as received, but will all be addressed no later than 04 September 2026 at COB. IMPORTANT: see page 23 of the solicitation document for full information on the site visit and all instructions for submission of offers. --------------------------------------------- From the SOW: The customer mentioned has a requirement for the renovation of secure facility B1049. The primary objective of this project is to construct a newly enclosed storage space 25 feet x 25 feet, featuring a mezzanine above. Prior to the start, contractor shall remove existing Space Saver storage system in its entirety. Access to the Mezzanine will be provided by a metal staircase. The lower storage is designated for miscellaneous equipment storage, while the mezzanine will accommodate small to medium electronic devices. Additionally, four (4) opaque skylights will be installed. Modify and relocate utilities as necessary. The contractor shall encompass, without limitation, the following responsibilities: performing field verifications; supplying all necessary labor, tools, equipment, permits, and licenses; and executing the project construction in full compliance with the specifications detailed in the project's SOW.